Fluorescent-lamp formats

Since their introduction as a commercial product in 1939, many different types of fluorescent lamp have been introduced. Systematic nomenclature identifies mass-market lamps as to overall shape, power rating, length, color, and other electrical and illuminating characteristics.

Fluorescent lamps in various embodiments

Tube designations

edit

In the United States and Canada, lamps are typically identified by a code such as FxxTyy, where F is for fluorescent, and the first number (xx) indicates either the power in watts for bi-pin lamps, length in inches for single-pin and high-output lamps, and for circular bulbs, the diameter of the circular bulb. The T indicates that the shape of the bulb is tubular, and the last number (yy) is the diameter in eighths of an inch (sometimes in millimeters, rounded up to the nearest millimeter). Typical diameters are T12 or T38 (1+12 in or 38 mm) for larger, often less efficient lamps, T8 or T26 (1 in or 25 mm) for smaller and often energy-saving lamps, and T5 or T16 (58 in or 16 mm) for very small lamps, which may even operate from a battery-powered device.

Fluorescent tube diameter designation comparison
DesignationTube diameterExtra
(in)(mm)SocketNotes
T214 approx.7WP4.5×8.5d
T41212.7G5 bi-pinSlim lamps. Power ratings and lengths not standardized (and not the same) between different manufacturers
T5T165815.9
  • G5 bi-pin
  • 2GX13 quad-pin
  • G10q quad-pin
  • Original 4–13 W miniature fluorescent range from 1950s or earlier.[1]
  • Two newer ranges, high-efficiency (HE) 14–35 W, and high-output (HO) 24–80 W, introduced in the 1990s.[2]
  • Panasonic's range of FHL fluorescent tubes in 18W, 27W, and 36W varieties for the Japanese market.
  • Circular fluorescent tubes.
  • Thorn/General Electric 2D fluorescent lamps and other similar lamps from various manufacturers.
T63419.05
  • Fa8 single-pin
  • G10q quad-pin
  • Single-pin fluorescent lamps.
  • Thorn/General Electric 2D fluorescent lamps and other similar lamps from various manufacturers.
T8T26125.4
  • G13 bi-pin
  • Fa8 single-pin
  • R17d recessed double contact
One of the first diameters of fluorescent lamps, with the 15W T8 and 30W T8 having been introduced in 1938.[3] The European energy-saving krypton T8 lamps were introduced by Thorn EMI during the 1970s.[4] The North American energy-saving argon T8 lamps weren't introduced until the 1980s.[5]
T9T291+1828.6
  • G10q quad-pin
  • G13 bi-pin
  • Circular fluorescent tubes
  • Some linear tubes
T101+1431.75
  • G13 bi-pin
  • G10q quad-pin
  • High-lumen retrofit lamps for 40W T12 lamps in North America.
  • Popular tube diameter in Japan
  • Circular 32W and 40W T10 lamps (Older versions of the 32W and 40W T9 lamps)
T12T381+1238.1
  • G13 bi-pin
  • Fa8 single-pin
  • R17d recessed double contact
One of the first diameters of fluorescent lamps, with the 15W T12 and 20W T12 having been introduced in 1938. These aren't as efficient as newer lamp options.[6]
T172+1854G20 Mogul bi-pinLarge size for 90W T17 (preheat) and 40W T17 (instant start)
PG172+1854R17d Recessed double contactGeneral Electric's Power Groove tubes

For T2–T12 and T17, the number indicates the tube diameter in 18 inches, e.g. T2 → 28 in and T17 → 178 in. Whereas for T16 and T26–T38, the number indicates the approximate tube diameter in millimeters.

Reflectors

edit
Cross section of a typical fluorescent lamp with and without a reflector

Some lamps have an internal opaque reflector. Coverage of the reflector ranges from 120° to 310° of the lamp's circumference.

Reflector lamps are used when light is only desired to be emitted in a single direction, or when an application requires the maximum amount of light. For example, these lamps can be used in tanning beds or in backlighting electronic displays. An internal reflector is more efficient than standard external reflectors. Another example is color matched aperture lights (with about 30° of opening) used in the food industry for robotic quality control inspection of cooked goods.

Aperture lamps have a clear break in the phosphor coating, typically of 30°, to concentrate light in one direction and provide higher brightness in the beam than can be achieved by uniform phosphor coatings. Aperture lamps include reflectors over the non-aperture area. Aperture lamps were commonly used in photocopiers in the 1960s and 1970s where a bank of fixed tubes was arranged to light up the image to be copied, but are rarely found nowadays. Aperture lamps can produce a concentrated beam of light suitable for edge-lit signs.

Single-pin lamps

edit

Single-pin lamps (Also generically called "Slimline" in the United States) operate on an instant start ballast in the United States and Canada or on a series choke without a starter in 220-240V countries.

High-output/very high output lamps

edit

High-output lamps are brighter and are driven at a higher electric current. They have a recessed double contact (R17d) base on each end, rather than a standard bi-pin base, which prevents them from being installed into the wrong fixture. Since about the early to mid-1950s to today, General Electric has developed and improved the Power Groove lamp. These lamps are recognizable by their large diameter (2+18 in or 54 mm) and grooved tube shape.

Colors

edit

Colors using a halophosphate formulation are usually indicated by WW for warm white, W for (neutral) white, CW for cool white, and D for the bluish daylight white.

Philips and Osram use numeric color codes for tri-phosphor and multi-phosphor colors. The first digit indicates the color rendering index (CRI) of the lamp. If the first digit on a lamp says 8, then the CRI of that lamp will be approximately 85. The last two digits indicate the color temperature of the lamp in kelvins (K). For example, if the last two digits on a lamp say 41, that lamp's color temperature will be 4100 K, which is a common tri-phosphor cool white fluorescent lamp.

BL is used for ultraviolet lamps commonly used in bug zappers. BLB is used for blacklight-blue lamps employing a Wood's glass envelope to filter out most visible light, commonly used in nightclubs. Other non-standard designations apply for plant lights or grow lights.

Halophosphate tubes
Japanese color codeNumeric color codeAlphabetic color codeColorApproximate CRIColor temperature (K)
N/A29WWWarm white≈523000
WW35WWhite≈563500
W33CWCool White≈624000-4300
N/A25N/ANeutral/Universal White≈754000
NN/AN/ANatural Daylight≈705000
D54DDaylight≈756500
Deluxe halophosphate tubes
Japanese color codeNumeric color codeAlphabetic color codeColorApproximate CRIColor temperature (K)
L-EDL27N/ADeluxe Extra Warm White≈952700
N/AN/ASWGE Soft White (Lower-CRI WWX)≈773000
N/A32WWXDeluxe Warm White≈873000
N/AN/AWXSylvania White Deluxe≈853500
N/A79NNatural≈903600
N/A34N/ADeluxe White≈853850
W-SDL38CWXDeluxe Cool White/Kolor-rite≈904000
N/AN/AC41GE Cool White Utility (Enhanced CWX)≈874100
N-SDL, N-EDLN/AC50/DSGN50GE Chroma 50/Philips Colortone 50/Sylvania Design 50≈90-995000
D-SDL, D-EDL55DXDeluxe Daylight/Northlight/Colour Matching≈88-986500
N/AN/AC75GE Chroma 75/Philips Colortone 75≈927500
700-series tubes (halophosphate and tri-phosphor blend)
Numeric color codeAlphanumeric color codeColorApproximate CRIColor temperature (K)
730SP30/D30/TL730Warm White≈753000
735SP35/D35/TL735Neutral White≈753500
741SP41/D41/TL741Cool White≈754100
750SP50/TL750Natural Daylight≈755000
765SP65/TL765Cool Daylight≈756500
800-series tri-phosphor tubes
Japanese Color CodeNumeric color codeColorApproximate CRIColor temperature (K)
ELX825Sunset White≈852500
ELR, ELC827, 828Extra Warm white≈852700, 2800
EX-L, EL, ELK830Warm White≈853000
ELW832Warm White≈853200
EX-WW, EWW835Neutral White≈853500
EW38838Neutral White≈853800
EX-W, EW840, 841, 842Cool White≈854000, 4100, 4200
EX-N, EN850Natural Daylight≈855000
ENW, ENM, ENC852, 853Natural Daylight≈855200, 5300
ENK855Natural Daylight≈855500
ENX858Natural Daylight≈855800
EDW862Cool Daylight≈856200
EX-D, ED865, 867Cool Daylight≈856500, 6700
ECW, EDK, EDC872, 874Cool Daylight≈857200, 7400
EDF, EDX880Skywhite≈858000
Multi-phosphor tubes
Numeric color codeColorApproximate CRIColor temperature (K)
927Warm white≈952700
941Cool white≈954100
950Natural Daylight≈985000
965Cool daylight≈956500
Special purpose tubes
Numeric codeAlphabetic CodeFluorescent

lamp type

Notes
05N/AGermicidal lampsNo phosphors used in these lamps at all, and the enveplope is made of fused quartz instead of glass.

In the American lamp code, the F as in FxxTyy is replaced by a G as in GxxTyy, indicating that it's a germicidal lamp.

08BLBBlack-Light Blue lampsThese lamps are similar to the regular black light lamps, except they use wood's glass as a filter to reduce the amount of visible light emitted. These lamps are used for fluorescence effects where less visible light is ideal.
09N/ASun-tanning lampsThese lamps produce wide or narrow band UV-B radiation
10BLBlack-Light lampsBlack light lamps give off long-wave UV-A radiation of around 350-400 nm. They are often used to attract insects to traps. Unlike black light blue lamps, these lamps do not use wood's glass. They use regular soda-lime glass and emit more visible light than BLB lamps.

Common tube ratings

edit

This section lists the more common tube ratings for general lighting. Many more tube ratings exist, often country-specific. The Nominal Length may not exactly match any measured dimension of the tube. For some tube sizes, the nominal length (in feet) is the required spacing between centers of the lighting fixtures to create a continuous run, so the tubes are a little shorter than the nominal length.

Tube diameter in 18 in (3.175 mm)Nominal lengthNominal power (W)Lamp Code
T5 Miniature6 in (152 mm)4F4T5
T5 Miniature9 in (229 mm)6F6T5
T5 Miniature12 in (305 mm)8F8T5
T5 Miniature21 in (533 mm)13F13T5
T5/HE22 in (560 mm)14F14T5
T5/HE34 in (860 mm)21F21T5
T5/HE46 in (1,200 mm)28F28T5
T5/HE58 in (1,500 mm)35F35T5
T5/HO22 in (560 mm)24F24T5/HO
T5/HO34 in (860 mm)39F39T5/HO
T5/HO46 in (1,200 mm)54F54T5/HO
T5/HO58 in (1,500 mm)80F80T5/HO
T815 in (381 mm)14F14T8
T818 in (460 mm)15F15T8
T82 ft (610 mm)17F17T8
T82 ft (610 mm)18N/A
T83 ft (914 mm)25F25T8
T83 ft (914 mm)30F30T8
T84 ft (1,219 mm)32F32T8
T84 ft (1,219 mm)36N/A
T85 ft (1,524 mm)40F40T8
T85 ft (1,524 mm)58N/A
T86 ft (1,829 mm)70N/A
T8 single-pin6 ft (1,829 mm)38F72T8
T8 single-pin8 ft (2,438 mm)51F96T8
T8 single-pin8 ft (2,438 mm)59F96T8
T8/HO4 ft (1,219 mm)44F48T8/HO
T8/HO5 ft (1,524 mm)55F60T8/HO
T8/HO6 ft (1,829 mm)65F72T8/HO
T8/HO8 ft (2,438 mm)86F96T8/HO
T1215 in (381 mm)14F14T12
T1218 in (457 mm)15F15T12
T122 ft (610 mm)20F20T12
T123 ft (914 mm)30F30T12
T124 ft (1,219 mm)40F40T12
T125 ft (1,524 mm)65N/A
T125 ft (1,524 mm)80N/A
T126 ft (1,829 mm)75N/A
T126 ft (1,829 mm)85N/A
T128 ft (2,438 mm)125N/A
T12 single-pin4 ft (1,219 mm)39F48T12
T12 single-pin6 ft (1,829 mm)55F72T12
T12 single-pin8 ft (2,438 mm)75F96T12
T12/HO4 ft (1,219 mm)60F48T12/HO
T12/HO5 ft (1,524 mm)75F60T12/HO
T12/HO6 ft (1,829 mm)85F72T12/HO
T12/HO8 ft (2,438 mm)110F96T12/HO
T12/VHO4 ft (1,219 mm)115F48T12/VHO
T12/VHO6 ft (1,829 mm)160F72T12/VHO
T12/VHO8 ft (2,438 mm)215F96T12/VHO

European energy-saving tubes

edit

In the 1970s, Thorn Lighting introduced an energy-saving 8 ft retrofit tube in Europe. Designed to run on the existing 125 W (240 V) series ballast but with a different gas fill and operating voltage, the tube operated at only 100 W. Increased efficiency meant that the tube produced only 9% lumen reduction for a 20% power reduction.[7] This first energy-saving tube design remains a T12 tube even today. However, follow-on retrofit replacements for all the other original T12 tubes were T8, which helped with creating the required electrical characteristics and saving on the then new (and more expensive) polyphosphor/triphosphor coatings, and these were even more efficient. Note that because these tubes were all designed as retrofit tubes to be fitted in T12 fittings running on series ballasts on 220–240 V supplies, they could not be used in 120 V mains countries with inherently different control gear designs.

TypeDiameter (in, mm)Nominal length (ft, m)Nominal power (W)Notes
T81.0, 252, 0.618Retrofit replacement for 2 ft T12 20 W
T81.0, 254, 1.236Retrofit replacement for 4 ft T12 40 W
T81.0, 255, 1.558Retrofit replacement for 5 ft T12 65 W
T81.0, 256, 1.870Retrofit replacement for 6 ft T12 75 W
T121.5, 388, 2.4100Retrofit replacement for 8 ft T12 125 W

Around 1980 (in the UK, at least), some new fluorescent fittings were designed to take only the newer, retrofit tubes (the lamp holders are designed not to take T12 tubes, except for 8 ft length). The earlier T12 halophosphate tubes still remained available as spares until 2012. They fit in older fittings and some modern fittings that employ twist lock lamp holders, even though the modern fittings were not electrically designed for them.

US energy-saving tubes

edit

In the 1970s, 34-watt energy-saving F40T12 fluorescent lamps were intoroduced in the United States. In the 1980s, T8 32-watt lamps were introduced,[8] but unlike the T8 tubes introduced in Europe, these T8s are not retrofits and require new matching ballasts to drive them. These ballasts were originally magnetic, but most today are electronic. The energy-saving T12 lamps are made to operate on ballasts designed for 40-watt F40T12 lamps, though some F40T12 ballasts are not be designed to operate these lamps, and can overheat if energy-saving lamps are used. Running an energy-saving T8 tube with a ballast for T12 will reduce lamp life and can increase energy consumption.[9] Conversely, a T12 tube on a T8 ballast will usually draw too much power and so may burn out the ballast, unless it is within the range that particular ballast can compensate for. The tube type should always match the markings on the light fixture.

TypeDiameter (in, mm)Nominal length (ft)Nominal power (W)Lamp CodeNotes
T50.625, 16449F49T5Retrofit replacement for 4 ft T5HO 54 W
T81.0, 25425F32T8/25wRetrofit replacement for 4 ft T8 32 W
T81.0, 25428F28T8

F32T8/28w

Retrofit replacement for 4 ft T8 32 W
T81.0, 25430F32T8/ESRetrofit replacement for 4 ft T8 32 W
T81.0, 25217F17T8Ballast-swap replacement for 2 ft T12 20 W
T81.0, 25325F25T8Ballast-swap replacement for 3 ft T12 30 W
T81.0, 25432F32T8Ballast-swap replacement for 4 ft T12 40 W
T81.0, 25859F96T8Ballast-swap replacement for 8 ft T12 75 W single-pin
T121.5, 384"25"F40UTSLRetrofit replacement for 4 ft T12 40 W on underpowered residential-grade rapid start magnetic ballasts. These are F40CW lamps made with

lighter cathodes that can only handle a lower amount of power. They will function as a standard 40 W lamp on full-power ballasts, but may not last as long. These lamps are typically rated to last for 12,000 hours on a residential-grade ballast and only 6000 hourson a commercial-grade one.

T121.5, 38432F40T12/ESPRetrofit replacement for 4 ft T12 40 W
T121.5, 38434F34T12

F40T12/ES

Retrofit replacement for 4 ft T12 40 W
T121.5, 38860F96T12/ESRetrofit replacement for 8 ft T12 75 W single-pin
T121.5, 38895F96T12/HO/ESRetrofit replacement for 8 ft T12 110 W high-output

T5 tubes

edit

In the 1990s, longer T5 tubes were designed in Europe (making it to North America in the 2000s), in addition to the shorter ones (mentioned above) already in use worldwide. Like the European modular furniture, display cabinets, ceiling tile grids, etc. they were designed for, these are based on multiples of the 300 mm (11.8 in) "metric foot" instead of the 12 in (305 mm) imperial foot, but are all 37 mm (1.5 in) shorter to allow space for the lampholder connections within the 300 mm modular units, and for much easier insertion into and removal from troffer lights within a grid.

Tube diameter is 58 in (15.875 mm)LengthNominal power (W)Notes
High-efficiencyHigh-output
T5563 mm (22.2 in)1424Fits within a 0.6 m modular unit
T5863 mm (34.0 in)2139Fits within a 0.9 m modular unit
T51,163 mm (45.8 in)2854Fits within a 1.2 m modular unit
T51,463 mm (57.6 in)3580Fits within a 1.5 m modular unit

The T5 diameter is nearly 40% smaller than T8 lamps and almost 60% smaller than T12 lamps. T5 lamps have a G5 base (bi-pin with 5 mm spacing), even for high-output (HO and VHO) tubes.[10]

See also

edit

References

edit
  1. ^ Funke and Oranje, "Gas Discharge Lamps"; N.V Philips' Gloeilampenfabrieken (1951)
  2. ^ "The T5 Fluorescent Lamp: Coming on Strong". 1 September 2003. Retrieved 20 February 2020.
  3. ^ "Covington, E. J. The Story Behind This Account of Fluorescent Lamp Development". Archived from the original on 24 March 2007. Retrieved 28 September 2008.
  4. ^ "The Fluorescent Lamp – Gas Fillings". lamptech.co.uk. Retrieved 30 August 2023.
  5. ^ "Lawrence Berkeley National Laboratory: T-8 lamp retrofits". Archived from the original on 16 September 2008. Retrieved 28 September 2008.
  6. ^ "Lawrence Berkeley National Laboratory: History and problems of T12 fluorescent lamps". Archived from the original on 16 September 2008. Retrieved 28 September 2008.
  7. ^ Thorn Lighting Technical Handbook
  8. ^ "4-Foot T-8 Fluorescent Lamp Upgrading". Retrieved 2 November 2022.
  9. ^ "Energy Codes". 1 November 1995. Archived from the original on 22 May 2011.
  10. ^ Lighting Research Center, "T5 Fluorescent Systems", [1], accessed 11-30-2009.